GRACO 16M167 - Informer Upgrade Power Supply Module
Intrinsically safe (I.S.) power supply module designed for hazardous location applications, providing reliable power for ProControl 1KE systems with 100-240 VAC input flexibility and includes essential mounting hardware for easy installation
Specifications
- Classification: Single I.S. barrier
- Type: Power module
- Input Voltage: 100-240 VAC
- Output Voltage: 15.75 V
- Safety Rating: Intrinsically safe (I.S.)
- Cable Length: 15 m (50 ft) I.S.
- Output Current: 723 mA
- Output Power: 2.84 W
- Output Capacitance: 5.38 µF
- Output Inductance: 570 µH
Features
- Single intrinsically safe barrier design
- Alternative to full G-barrier power modules
- Designed for hazardous locations
- Intrinsically safe (I.S.) certification for hazardous locations
- Wide input voltage range (100-240 VAC)
- 15 VDC output
Applications
- Hazardous location installations
- Applications not requiring full G-barrier capabilities
- Hazardous location fluid dispensing
- Industrial process control systems
- ProControl 1KE system power supply
- Intrinsically safe power requirements
Compatible Equipment
- 1KE Plus models
- Fluid and atomizing air control systems
- ProControl 1KE systems
- CLASS I, DIVISION 2 hazardous locations
- intrinsically safe Entity connections CLASS I, II, III, DIVISION 1
Related Parts
- 26C724 - Module, G-Barrier, Power Supply, 50 PSI
- 16V680 - 15 VDC, 1.20A, 18W Power Supply
Kit Contents
- Power supply module
- 15 m (50 ft) I.S. power cable
The 16M167 Single I.S. barrier power module has power limitations and cannot be used on 1KE Plus units that require greater than 50 PSI of fluid pressure or pilot air pressure for alternate air-operated fluid regulator use or on units that control fluid and atomizing air See page 6 for important information on proper power selection. This is the intrinsically safe version compared to the non-intrinsically safe 16V680 model. Single Barrier Channel. For use in CLASS I, DIVISION 2 hazardous locations and provides intrinsically safe Entity connections. Has various approvals including CE, FM, UL, and CSA. Entity parameters and hazardous location information are from Pepperl+Fuchs Barrier Product Data Sheets.
Reference Manuals
- 345008 (Page 6) ProControl 1KE Plus
- 332196 (Page 3) IS Power Supply Modules
- 332356 (Page 4) Communication Kits
- 3A2040 (Page 31) Informer® Fluid Monitoring Kits