GRACO 26C724 - Module, G-Barrier, Power Supply, 50 PSI
G-barrier intrinsically safe (I.S.) power module that provides up to three I.S. power output circuits for safe operation in hazardous environments, with 100-240 VAC, 50/60 Hz input and includes one I.S. 15 m (50 ft) I.S. power cable
Specifications
- Max Working Pressure: greater than 3.4 bar (50 PSI) fluid pressure capability
- Barrier Type: G-Barrier
- Location Rating: hazardous locations
- Input Voltage: 100-240 VAC
- Frequency: 50/60 Hz
- Output Circuits: up to three I.S. power output circuits
- Safety Rating: Intrinsically safe (I.S.)
- Cable Included: 15 m (50 ft) I.S. power cable
- Output Voltage: 16.4 V
- Output Current: 592.2 mA
- Output Power: 2.82 W
- Output Capacitance: 2.4 µF
- Output Inductance: 64 µH
- Channels: 3 Channel
- Temperature Range: 0°C ≤ Ta ≤ 54°C
Features
- G-barrier power module for hazardous locations
- Powers multiple 1KE Plus units from one module
- Supports up to three units from single power module
- Handles greater than 3.4 bar (50 PSI) fluid pressure applications
- Compatible with 1KE Plus models requiring fluid and atomising air control
- G-barrier intrinsically safe design
Applications
- Hazardous location spray applications
- Fluid and atomising air control systems
- Multi-unit 1KE Plus installations
- High pressure fluid applications over 3.4 bar (50 PSI)
- Hazardous environment power supply
- Intrinsically safe system power distribution
Compatible Equipment
- 1KE Plus models 25B296-24B299
- 1KE Plus units with standard 1:1 24C375 fluid regulator
- Units using alternate air-operated fluid regulator
- CLASS I, DIVISION 1, GROUP D (USA & CANADA)
- CLASS I, ZONE 0, [AEx ia Ga] IIA (USA)
Related Parts
- 16M167 Single I.S. barrier power module
- 16V680 - 15 VDC, 1.20A, 18W Power Supply
- 16M167 - Informer Upgrade Power Supply Module
Kit Contents
- One I.S. 15 m (50 ft) I.S. power cable
Order this module if you answered YES to ANY of the qualifying questions about 1KE Plus usage, future upgrades, powering multiple units, or high pressure applications. The 16M167 Single I.S. barrier power module is an alternative for simpler applications. Part of the Power supply category with important information on proper power selection referenced on page 6 Entity parameters and hazardous location information are from Pepperl+Fuchs Barrier Product Data Sheets. Each of the three output channels have the same entity parameters. See manual 3A5056 for more detailed information about the G-Barrier. Certified to various standards including IECEx FMG 18.0022, FM18ATEX0053, FM18US0213, FM18CA0102.
Reference Manuals
- 345008 (Page 6) ProControl 1KE Plus
- 332196 (Page 3) IS Power Supply Modules
- 3A6948 (Page 8) ProControl™ 1KE Plus Models for Management of Fluid and Air